
But as the uPA activity accounts for at least 50 % of activity for cleave plasminogen to plasmin, the kit can at least provide a reference for uPA activity when samples are compared although we would recommend ab108916 if the samples have enough uPA. However, if a plasma or serum sample is used, it is difficult to differentiate from tPA activity. Key words: Floating thrombus, tPA, endovascular stent placement.
Plasminogen activator Activator#
If a cell culture sample specific for uPA expression is used, ab108915 will works well. treatment of FT in the ICA using intra-arterial tissue plasminogen activator and stenting. We provide uPA standard for indirect assay is for reference of uPA activity. ab108915 is more sensitive assay but is no able to differentiate uPA vs. tPA activity, however, it is not as sensitive as ab108915 which is an indirect assay. A large body of evidence support that among the various components of the PA system, urokinase-type plasminogen activator (uPA), its receptor (uPAR), and plasminogen activator inhibitor-1 and -2 (PAI-1 and PAI-2) play a major role in tumor. This kit is using a plasmin substrate to measure uPA activity. The plasminogen activator (PA) system is an extracellular proteolytic enzyme system associated with various physiological and pathophysiological processes. 1 When the body does not have enough functional PAI1, the body's ability keep blood clots intact is impaired. 1 2 3 PAI1 is a protein in the body needed for normal blood clotting. On the other hand, we also have an indirect uPA activity kit which is ab108915. Plasminogen activator inhibitor type 1 (PAI1) deficiency is a rare bleeding disorder that causes excessive or prolonged bleeding due to blood clots being broken down too early. This assay can differentiate uPA activity vs. The uPA substrate is specifically designed for its specificity for uPA. One is ab108916 which is direct using uPA substrate to generate the color. The entire kit may be stored at -20☌ for long term storage before reconstitution - Avoid repeated freeze-thaw cycles.įor uPA activity kits, we have two types of kit. The change in absorbance of the pNA in the reaction solution at 405 nm is directly proportional to the uPA enzymatic activity. The amount of plasmin produced is quantitated using a highly specific plasmin substrate releasing a yellow para-nitroaniline (pNA) chromophore. The assay measures the ability of uPA to activate the plasminogen to plasmin in coupled or indirect assays that contain uPA, plasminogen, and a plasmin-specific synthetic substrate. High level of uPA is a poor prognostic marker for aggressive breast cancer, aggressive prostate cancer, bladder cancer and gastric cancer.Īb108915 uPA Human Chromogenic Activity Assay Kit is developed to determine Human uPA activity in plasma and cell culture supernatants. Binding of uPA to its receptor and subsequent uPA mediated pericellular proteolysis are involved in many process including cell migration and tissue remodelling in angiogenesis, atherogenesis, tumor cell metastasis, and ovulation. Urokinase type plasminogen activator (uPA) is a highly restricted serine protease that converts the zymogen plasminogen to active plasmin, a broad-spectrum serine proteinase capable of degrading most of the major protein components of the extracellular matrix.
